Enable two-way callback: For this option to be used, at least one activation must be programmed to enable two-
way voice/listen-in with the central station. After the digital communication, with this
option enabled, the system will hang up and wait for the programmed time in location
0461 for a call back from the central station. The dialer LED will blink while waiting
for the return call. The system will answer after the first ring and will automatically be
in two-way with listen-in or will issue three beeps requesting a valid access code. If
this option is not programmed, the system will hold the line after the kiss-off tone and
will be in two-way listen in mode. See the "Communicator" for two-way callback
options. Two-way callback is not evaluated for UL installation.
System Options - Group 4
No Program Mode Entry With this option set, the system will not enter program mode with the panel armed.
When Armed:
Suppress dialing during With this option set, the panel will only send new activation information to the central
two-way callback: station after a two-way callback call is complete. If this option is not set, a two-way
session can be terminated by the panel to allow additional information to be sent.
Two-way callback is not evaluated for UL installation.
System Options - Group 5
Speak auxiliary zone type:When this option is programmed and "Show open status at the keypad" is selected for an
auxiliary zone type, the system will speak the zone description when the zone is
opened.
STATUS on local phone: With this option selected the system will speak the system status instead of the
acceptance tone when you access the system from local phones.
Silence inside speaker in With this option selected, status, keypad echo and pre-alarm sounds to the inside
HOME/Night mode: speakers will be silenced when the system is armed to HOME or Night. Alarm
activations will continue to sound. This option may be used in a home where someone
is often coming home late at night and they do not want to disturb others when they
arrive. This feature is not permitted in a UL installation and is not available when "Split
Arming" is enabled.
Speak extended monitor: When this option is programmed, during an extended monitor the system will repeatedly
speak the zone description instead of activating a series of beeps.
Disable force arming: When this option is programmed, the system will not arm if zones are open unless the
system is armed from an Arm/Disarm zone input. This option must be enabled in a UL
installation.
System Options - Group 6
Speak remote menu: When this option selected, entering Remote Control will speak a menu based on the
remote control words programmed. The system will scroll through all active channels
until a valid channel is selected.
Speak time and date: With this option enabled, the system will speak time and date whenever a user requests
time (user code followed by 1).
Speak temperature: Speaks TS16 description and temperature after time is spoken. See Using a TS16.
Answering Machine If an answering machine is used on the same phone line as the control panel, the
Override Digit: answering machine override feature in the panel must be used. Once the answering
machine answers the line, enter the override digit. The system will respond with an
access confirmation tone.