Speaker (Bell) Supervision
Speaker supervision requires the connection of a jumper wire from the speaker output terminal (INT or EXT) to a
selected hardwire input terminal and two 4.7K resistors in parallel be connected between the (AUX+) terminal and
the selected hardwire input terminal where the jumper is attached.
UL requires that at least one internal speaker, excluding RK series keypad speaker(s), must be supervised and
connected to the "EXT" and "COM" terminals. Supervised speaker(s) must be connected to one of the 16 on-board
hardwire inputs. The option programming location for the hardwire input to be supervised as a speaker zone (see
page 26) must have a value of 008. With a value of 008 programmed, an open or short in the speaker wire will
cause a trouble condition. To have a trouble condition be treated as an activation, program 024 in the hardwire
input option location.
If multiple speakers are connected are needed for supervision, they must be connected in series. This way, any
break in the loop will be properly detected. All speakers connected in series must have similar ratings.
NOTE: The panel common must not be connected to an earth ground. The speaker supervision
will not detect aground fault if the panel is grounded. Earth ground is not required in UL
installations.
If a loop programmed as a speaker supervision zone does not have the option set to "treat trouble as an activation"
the panel will display trouble at the keypad and send trouble/ trouble restore reports to the central station.
If programmed to "treat trouble as activation", the panel will treat the speaker supervision as any other zone. You
may program the zone to any legal zone type.
Smoke Detector Low Battery Warning
Upon detection of a low battery from a transmitting device assigned as a Fire zone type, the panel will start a
warning beep, the STATUS LED will flash the low battery condition will be displayed (RKLCD keypads only).
Pressing the STATUS key will silence the warning beeps, the STATUS LED will remain solid. The low battery
condition will continue to be displayed on the RKLCD.
UL requires the low battery warning feature alert the homeowner of a continuing low battery condition at least
every 4 hours until such time that battery is replaced. If a low battery condition still exists, within 4 hours the
panel will restart the warning as described above.
Note: If programmed a transmitter low battery warning report (see Zone Options 1) will be sent to
the Central Station upon initial activation of condition. If programmed a transmitter low battery
restore report will be sent to Central Station when condition is corrected.
RF Jam Detection
RF jam detection feature senses when a radio receiver is being jammed or an interference exists which could
possibly prevent proper operation of the receiver. The receiver will detect any interference that persists for 20
seconds or longer. The Bridge board polls each receiver every 30 seconds for a jamming condition. A jam
condition is detectable within a maximum of 60 seconds of the 20 second (or longer) interference.
A detected RF jam causes the panel to produce a trouble warning beep and flashing of the STATUS LED on the
keypad. Pressing the STATUS key will silence the beeping and cause the panel to speak the message, "Receiver
Overload". The status condition will clear when the interfering signal goes away.
Note: No central station reports are associated when this condition is detected.