Hardware Device Types
Hardwire Inputs
Type Description Value
System Controller
.........................................
16 hardwire inputs
..................................................
000
HWB416
.......................................................
16 Zone expansion board
.......................................
001
System Smoke Loop
......................................
2-Wire smoke loop
.................................................
002
Local Telephone
...........................................
Local telephone 5 zero activation
.........................
015
Phone Line Monitor
......................................
Loss of phone line activation
.................................
021
TS16 -only use 32-127 degrees F
...................
Temperature Sensor
................................................
022
Alarm Point Transmitters
Type Description Value
5816 (MN)
....................................................
2 input alarm point transmitter
..............................
003
*5816TEMP
.....................................................
Low temperature transmitter
..................................
004
5817
..............................................................
3 input alarm point transmitter
..............................
005
5818
..............................................................
Recessed door transmitter
......................................
006
*5819
..............................................................
3 input shock transmitter
.......................................
007
5890
..............................................................
Passive Infrared
......................................................
011
5849
..............................................................
Shock / Glass Detector
..........................................
012
5806
..............................................................
Smoke Detector
.....................................................
018
5807
..............................................................
Smoke Detector
.....................................................
018
5808
..............................................................
Smoke Detector
.....................................................
019
* Not evaluated for UL installation
Button Type Devices - PROGRAM ZONE TYPE AS 015
Type Description Value
5801
..............................................................
4 button portable
.....................................................
008
*5802
..............................................................
1 button portable
.....................................................
016
*5802 CP
........................................................
1 button portable
.....................................................
017
*5802 MN
......................................................
1 button portable
.....................................................
009
5804
..............................................................
4 button portable
.....................................................
010
X-10
..............................................................
X-10 Channel On/Off Command
.............................
020
Keypad
..........................................................
Keypad alert activations
.........................................
013
* Not evaluated for UL installation
Predefined Zone Assignments
From a defaulted panel the following zones are automatically assigned:
Zone 94: Local phone This is predefined to allow local phone access at default. To enable a
5 "0" activation as an input, assign a zone type to zone 94.
Zone 95: Phone Line Monitor & The phone line monitor device type must be assigned to a zone for
remote
Remote Phone phone "User Code + Digit" activations. To enable the phone monitor,
assign a zone type (recommended zone type: aux) to zone 95. When a
phone line loss occurs, the zone will show open and beep the keypad as
a trouble violation. Pressing the status button silences the beep.
Zone 96: Hardwire keypad All keypad activations for RKLED and RKLCD(#1) are defaulted to report
as zone 96.