AMX DESIGN XPRESS V 1.5 - PROGRAMMER GUIDE Instrukcja Użytkownika Strona 22

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 52
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 21
DRAFT
December 16, 2004 3:54 pm, GSG_Chapter_4-02.fm
Chapter 2 Designing Primers and Probes for Quantification Assays
Manually Designing Primers and Probes
Primer Express Software 3.0 Getting Started Guide 15
Notes
2
5 end – Cannot be a G residue. A G residue adjacent to the reporter dye
will quench the reporter fluorescence somewhat, even after cleavage.
Avoid the following motifs:
Repeating oligonucleotides– Avoid runs of identical nucleotides. If
repeats are present, there must be fewer than four consecutive G residues.
Consecutive A residues – Avoid six consecutive A residues anywhere in
the probe.
G residues on the 3 end – Avoid 5-...GGG-MGB-3 or
5-...GGAG-MGB-3
CC dinucleotides – Avoid two or more CC dinucleotides in the middle of
the probe (TaqMan MGB probes), which can sometimes reduce signal.
FAM
dye-labeled probes – If ordering FAM
-dye labeled probes,
avoid a G in the second position on the 5 end.
For secondary structure design considerations, see Primer Express Software Version
3.0 Online Help.
Note: If you cannot achieve the recommended Tm, you can design using the
complementary sequence. For more information, see Primer Express Software Version
3.0 Online Help.
7. Once the correct Tm is achieved, return to the Sequence tab and highlight the
sequence found in the Probe 1 field of the Primer Probe Test Tool. To manually
design primers, go to “Manually Designing the Primers” on page 16.
8. To automatically find primers after manually designing the probe, select Edit >
Annotate > Probe ( ). The selected probe sequence text is displayed in green.
For more information on annotating sequences, see Primer Express Software
Version 3.0 Online Help.
9. Select Tools > Find Primers/Probes ( ). Primer Express software performs its
calculations based on default parameter values. The status bar, located at the bottom
of the window, displays information about the progress of the calculations as the
software searches for primers based on the designed probe. If primers are found, go
to “Viewing Results” on page 16.
If primers were not found:
If the software does not find primers using default parameters, a pop-up will appear
stating that no acceptable primer pairs were found and that you can see the Interim
Results window. For more information on Interim Results, see Primer Express Software
Version 3.0 Online Help.
At this point, you can manually design primers described in “Manually Designing the
Primers” on page 16.
Przeglądanie stron 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 51 52

Komentarze do niniejszej Instrukcji

Brak uwag