Lutron® integration protocol
Example AREA Messages
Operation Command String
Execute: #AREA, Integration ID, Action Number, Parameters
Set area level to 75% (Fade = 4 sec, Delay = 2 sec) #AREA,2,1,70,4,2<CR><LF>
Lower Area #AREA,2,3<CR><LF>
Query: ?AREA, Integration ID, Action Number
Is the area occupied? ?AREA,2,8<CR><LF>
What is the current active scene? ?AREA,2,6<CR><LF>
Response: ~AREA, Integration ID, Action Number, Parameters
The area is currently occupied ~AREA,2,8,3<CR><LF>
Area Scene 2 is currently active ~AREA,2,6,2<CR><LF>