AMX NXB-CCG-K Informacje Techniczne Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 144
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 3
4
Lutron® integration protocol
Revisions to previous releases of the Lutron® Integration Protocol
Revision Update: O (continued)
HomeWorks® QS
TIMECLOCK Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . 65
Action added: Enable/Disable Event (#6)
GRAFIK Eye® QS
DEVICE Commands (Component Numbers) . . . . . . . . . . . . . . . . . . . . . . . . . 72, 73
Components added: Local CCI (#163); Timeclock Controller (#166),
Wireless Occupancy Sensor 1– 30 (#500 529); EcoSystem® Ballast
Occupancy Sensor 1– 64 (#700 –763)
“Not supported in QS Standalone” note added (#201, #210, #219, #228, #237,
#174, #175, #211, #183, #184, #220, #192, #193, #229)
DEVICE Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . . .73
Actions added: Scene Save (#12); Get/Set Timeclock State (#34)
Actions modified: Press/Occupied (#3); Release/Unoccupied (#4);
Get/Set Light Level (#14)
Parameter modified: QS Standalone fade/delay (#14)
OUTPUT Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . . . 74
Parameter modified: QS Standalone fade/delay (#1)
Energi Savr NodeTM QS for DALI®
DEVICE Commands (Component Numbers) . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Component added: Occupancy Sensors 1– 4 (#151– 154)
Component numbers changed: #301– 332 (formerly #201– 232)
DEVICE Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . . .76
Actions added: Report Occupied (#3); Report Unoccupied (#4); Scene Save (#12)
Parameter modified: QS Standalone fade/delay (#14)
OUTPUT Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . . . 77
Parameter modified: QS Standalone fade/delay (#1)
Energi Savr NodeTM QS with EcoSystem®
DEVICE Commands (Component Numbers) . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Components added: Occupancy Sensors 1– 4 (#136–139); Loop 1 Ballast
Occupancy Sensors (#140–203); Loop 2 Ballast Occupancy Sensors (#204–267)
DEVICE Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . . .79
Actions added: Report Occupied (#3); Report Unoccupied (#4); Scene Save (#12)
OUTPUT Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . . . 80
Parameter modified: QS Standalone fade/delay (#1)
Energi Savr NodeTM QS for 0 –10V/Softswitch®/Phase Adaptive
Phase Adaptive models added . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
DEVICE Commands (Component Numbers) . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Components added: Occupancy Sensors 1– 4 (#34 37);
Occupancy Sensors 1– 2 (#34 – 35)
DEVICE Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . . .82
Actions added: Report Occupied (#3); Report Unoccupied (#4); Scene Save (#12)
OUTPUT Commands (Action Numbers and Parameters) . . . . . . . . . . . . . . . . . . . . . 83
Parameter modified: QS Standalone fade/delay (#1)
Continued on next page…