How to Contact Altera Info–3
December 2013 Altera Corporation Cyclone V Hard IP for PCI Express
User Guide
How to Contact Altera
To locate the most up-to-date information about Altera products, refer to the following table.
November 2012 12.1
■ Added support for Root Ports when using the Avalon-MM Hard IP for PCI Express.
■ Add support for multiple MSI and MSI-X messages Avalon-MM Hard IP for PCI Express.
■ Corrected value of AC coupling capacitor in Table 18–1 on page 18–2. The correct value
is 0.1 uF.
■ Revised Qsys example design to include a separately instantiated Transceiver
Reconfiguration Controller IP Core and a software driver to program the Transceiver
Reconfiguration Controller.
June 2012 12.01
■ Added Chapter 18, Testbench and Design Example.
■ Updated Getting started chapters to include steps to simulate using the Root Port and
Endpoint BFMs described in the Testbench and Design Example chapter.
■ Added Avalon-MM interface support with full-featured and completer-only variants.
■ Added support for VHDL simulation.
■ Added support for dynamic reconfiguration of transceiver settings.
■ Added support for legacy interrupts.
■ Added
txswing
and
txmargin[2:0]
to the PIPE interface. This interface is available
for simulation only.
■ Removed
derr_cor_ext_rcv1
signal which is not used.
■ Removed
currentspeed[1:0]
and
dlup
signals from reset and status interface.
■ Corrected definition of flow control protocol error.
■ Corrected definition of
cpl_err[2]
. This signal only applies to non-posted requests.
■ Updated definition of
app_msi_req
to include the fact that in Root Port mode, the
header bit[127] of
rx_st_data
is set to 1 to indicate that the TLP being forwarded to
the Application Layer was generated in response to an assertion of the
app_msi_request
pin; otherwise, bit[127] is set to 0.
■ Removed
dlup
signal. Only
dlup_exit
is necessary.
■ Added
tl_app_int_sts_vec[7:0]
which replaces
app_inta–app_intd
signals.
■ Corrected explanation of Type 0 and Type 1 Configuration Space TLPs in Root Port
mode in Chapter 13, Flow Control.
■ Corrected size of RX buffer. It is 6 KBytes.
■ Removed fixedclk_locked signal.
■ Changed frequency range for Transceiver Reconfiguration Controller IP Core clock from
90–100 MHz to 100–125 MHz.
■ Corrected definitions of Avalon-MM to PCI Express interrupt registers in Table 8–25 on
page 8–12 and Table 8–26 on page 8–13.
November 2011 11.1 First release.
Contact
(1)
Contact Method Address
Technical support Website www.altera.com/support
Date Version Changes Made SPR
Komentarze do niniejszej Instrukcji