OFPC Project No. 703-039 M.D. ANDERSON CANCER CENTER
Ambulatory Clinical Building
55050.00
AV BID AUDIO VISUAL SYSTEM
03/11/04 11738 -16
L. Teleconference Mixer/Router (TMR-1) – ClearOne/Gentner XAP-800 teleconference mixer (quantity: 1)
with echo cancellation for each microphone input, 12 x 12 router and digital signal processing including
limiters and equalizers for each input and output. Unit to controllable via RS-232. Provide new, install in
AV rack, and integrate into system as shown in drawings.
M. Wireless Microphone System – Shure U14D/50-UB dual-channel body pack system including two
receivers (designated in drawings as WM-3 and WM-4), two bodypack transmitters, and two
omnidirectional lavalier microphones. Provide all new. Install receiver in AV Racks as shown in
drawings. Coordinate frequency selection with other radio-frequency sources in the area and with
manufacturer’s recommendations. Deliver transmitter, microphone, accessories, and unused batteries
(for transmitters) to Owner following Final Tests and Adjustments. Provide additional batteries for using
during tests and adjustments. Initially install provided antennas at rear of receiver (enclosed inside AV
Rack; i.e., the most secure location for antennas). Test performance of wireless systems while
transmitters are walked around all of the room. If reliable performance (without dropout or interference)
cannot be obtained with antennas mounted inside rack, then relocate antennas to positions outside of
rack. Propose new locations to Owner or Consultant, relocate antennas with necessary cabling, and
retest. Relocate a second time if necessary.
N. Audio Amplifier (AMP-2) – QSC CX-302 amplifier (quantity: 1). Provide new, install in AV rack, and
integrate into system as shown in drawings.
O. Interconnect Wiring – Provide and install following cable as required for connections in all areas. Meet
provisions of N.E.C.
Audio Plenum Rated Cable: West Penn 25452, West Penn 25291, or similar.
Composite Video Plenum Rated Cable: West Penn 25806
RGBHV Plenum Rated Cable: West Penn 258195 or Belden 1826A or Liberty RGB5C-SD-PLN.
Control Plenum Rated Cable: Control Plenum Rated Cable: West Penn D25350
Control CAT5E Plenum Rated Cable: West Penn 254245.
Loudspeaker plenum cable: West Penn 25226
P. Control System Ethernet Switch (CSS-1) Cisco Catalyst 2940-8TT fast Ethernet switch (quantity: 1).
Provide new, install in AV rack, and integrate into system as shown in drawings.
Q. Composite Video DA (VDA-8) Extron MDA 3V one composite video and three composite video outputs
distribution amplifier (quantity: 2). Provide new, install in AV rack, and integrate into system as shown in
drawings.
R. AMX Control AV Patch Panel (CVP-1) - Single rack panel with AMX NXA-AVB (AVI-1) breakout box.
(quantity: 1) mounted on side of rack. Provide six foot power breakout cable with 4-pin XLR to mini
phoenix connector (quantity: 2). Provide new, install in AV rack, and integrate into system as shown in
drawings.
S. Teleconference Mixer/Router/Interface (TMR-2) – ClearOne/Gentner XPA-400 teleconference mixer
(quantity: 1) with echo cancellation for each microphone input, 12 x 12 router and digital signal
processing including limiters and equalizers for each input and output. Unit to have integrated telephone
interface. Unit to controllable via RS-232. Provide new, install in AV rack, and integrate into system as
shown in drawings.
T. Genlock Video DA (VDA-6) Extron CVDA MX one composite video and six composite video outputs
distribution amplifier (quantity: 1). Provide new, install in AV rack, and integrate into system as shown in