Configuring the NXB-CCG
9
RPM Device Configuration Guide - NXB-CCG NetLinx Clear Connect Gateway
6. Change the ID for this sensor to match the Integration ID indicated in the RPM Project report.
FIG. 25 provides an example RPM Report entry for the CCD-OCRB-P Occupancy Sensor, indicating that the
sensor’s Integration ID is "12":
In this case, the ID in the WebConsole must be changed from the default value of 11 to match the Integration ID
value (12):
a. Click in the ID cell of the keypad to open an edit window (FIG. 17):
b. Enter the Integration ID that is indicated for the keypad in the RPM Project report.
c. Press Save to assign the new ID.
Adding a Dimmer
RPM supports the CCD-6NA dimmer (FIG. 27):
1. In the NXB-CCG’s WebConsole Add Devices page, click Add/Remove Devices to enter "add/remove devices
mode" (FIG. 28):
FIG. 25 RPM Project Report - CCD-OCRB-P Occupancy Sensor,
FIG. 26 NXB-CCG WebConsole - Device ID popup (Sensor)
FIG. 27 CCD-6NA dimmer
Status LEDs
Main "Paddle" button