Amx Signature Series NetLinx Integrated Controller NI- Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Amx Signature Series NetLinx Integrated Controller NI-. AMX Signature Series NetLinx Integrated Controller NI-3101-SIG User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - NI-3101-SIG

Operation/Reference GuideCentral ControllersNI-3101-SIGSignature Series NetLinxIntegrated ControllerLast Revised: 9/13/2011NI-3101-SIG Operation/Refer

Strona 2

viNI-3101-SIG Signature Series NetLinx Integrated ControllerTable of Contents

Strona 3

NetLinx Security within the Web Server90NI-3101-SIG Signature Series NetLinx Integrated Controller1. Click on the Create User Defined Device button (f

Strona 4

NetLinx Security within the Web Server91NI-3101-SIG Signature Series NetLinx Integrated Controller1. Decide whether the application interface is to be

Strona 5

NetLinx Security within the Web Server92NI-3101-SIG Signature Series NetLinx Integrated ControllerIf the Master is connected to the Internet, the Mo

Strona 6

NetLinx Security within the Web Server93NI-3101-SIG Signature Series NetLinx Integrated ControllerProblems with the certificate can result from:The

Strona 7

NetLinx Security within the Web Server94NI-3101-SIG Signature Series NetLinx Integrated Controller8. Click Next to proceed with the certificate import

Strona 8

NetLinx Security within the Web Server95NI-3101-SIG Signature Series NetLinx Integrated ControllerUsing your NetLinx Master to control the G4 panelRef

Strona 9

NetLinx Security within the Web Server96NI-3101-SIG Signature Series NetLinx Integrated Controller9. Click Ye s from the Security Alert popup window t

Strona 10 - Table of Contents

NetLinx Security within the Web Server97NI-3101-SIG Signature Series NetLinx Integrated ControllerWhat to do when a Certificate ExpiresSelf-generated

Strona 11 - Introduction

NetLinx Security within the Web Server98NI-3101-SIG Signature Series NetLinx Integrated Controller

Strona 12 - NI-3101-SIG Specifications

NetLinx Security with a Terminal Connection99NI-3101-SIG Signature Series NetLinx Integrated ControllerNetLinx Security with a Terminal ConnectionOver

Strona 13

Introduction1NI-3101-SIG Signature Series NetLinx Integrated ControllerIntroductionThe NI-3101-SIG Signature Series NetLinx Integrated Controller sati

Strona 14

NetLinx Security with a Terminal Connection100NI-3101-SIG Signature Series NetLinx Integrated ControllerEstablishing a Terminal connection via the RS-

Strona 15 - Installation and Upgrading

NetLinx Security with a Terminal Connection101NI-3101-SIG Signature Series NetLinx Integrated Controller12) Display Telnet Timeout in seconds 13)

Strona 16

NetLinx Security with a Terminal Connection102NI-3101-SIG Signature Series NetLinx Integrated Controller 5) ICSP Security...

Strona 17 - Connections and Wiring

NetLinx Security with a Terminal Connection103NI-3101-SIG Signature Series NetLinx Integrated ControllerOption 3 - Add user1.Type 3 and <Enter>

Strona 18 - AXlink Port and LED

NetLinx Security with a Terminal Connection104NI-3101-SIG Signature Series NetLinx Integrated ControllerAccess Rights MenuThe Access Rights Menu is ac

Strona 19 - Wiring Guidelines

NetLinx Security with a Terminal Connection105NI-3101-SIG Signature Series NetLinx Integrated ControllerOption 5 - Delete user1.Type 5 and <Enter&g

Strona 20

NetLinx Security with a Terminal Connection106NI-3101-SIG Signature Series NetLinx Integrated ControllerOr <ENTER> to return to previous menu

Strona 21 - Relay connections

NetLinx Security with a Terminal Connection107NI-3101-SIG Signature Series NetLinx Integrated ControllerEdit Group menu: List directory associations1.

Strona 22 - 8 76 45 321

NetLinx Security with a Terminal Connection108NI-3101-SIG Signature Series NetLinx Integrated Controller1) Add Directory Association2) Delete Director

Strona 23 - LAN RJ-45 Pinouts and Signals

NetLinx Security with a Terminal Connection109NI-3101-SIG Signature Series NetLinx Integrated ControllerMain Security MenuThe Main Security menu is de

Strona 24 - ETHERNET

Introduction2NI-3101-SIG Signature Series NetLinx Integrated ControllerNI-3101-SIG SpecificationsThe NI-3101-SIG (FIG. 1) provides support for 6 confi

Strona 25

NetLinx Security with a Terminal Connection110NI-3101-SIG Signature Series NetLinx Integrated ControllerDefault Security ConfigurationBy default, the

Strona 26

NetLinx Security with a Terminal Connection111NI-3101-SIG Signature Series NetLinx Integrated ControllerHelp menuType help at the prompt in the Telnet

Strona 27

NetLinx Security with a Terminal Connection112NI-3101-SIG Signature Series NetLinx Integrated ControllerHelp Menu Options (Cont.)Command DescriptionSE

Strona 28 - Setting the System Value

NetLinx Security with a Terminal Connection113NI-3101-SIG Signature Series NetLinx Integrated ControllerLogging Into a SessionUntil Telnet security is

Strona 29

NetLinx Security with a Terminal Connection114NI-3101-SIG Signature Series NetLinx Integrated ControllerSetup SecurityThe security command displays a

Strona 30

Programming115 NI-3101-SIG Signature Series NetLinx Integrated ControllerProgrammingThis section describes the Send_Commands, Send_Strings, and Channe

Strona 31 - Device Addressing dialog

Programming116NI-3101-SIG Signature Series NetLinx Integrated ControllerMaster Send_Commands (Cont.)Command DescriptionG4WCAdd G4 Web Control devices

Strona 32

Programming117 NI-3101-SIG Signature Series NetLinx Integrated ControllerMaster IP Local Port Send_CommandsThese commands are specific to the Master a

Strona 33

Programming118NI-3101-SIG Signature Series NetLinx Integrated ControllerDevice:Port:System (D:P:S)A device is any hardware component that can be conne

Strona 34

Programming119 NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionDEVICE HOLDOFF ON|OFFSe

Strona 35

Introduction3NI-3101-SIG Signature Series NetLinx Integrated ControllerNI-3101-SIG Specifications (Cont.)Input/Output LEDs White Output LED blinks whe

Strona 36

Programming120NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionGET ETHERNET MODEDisplay

Strona 37 - New TCP/IP Setting dialog

Programming121 NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionON <D:P:S, NAME, CHA

Strona 38

Programming122NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionREBOOT <D:P:S>Rebo

Strona 39

Programming123 NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionSET DNS <D:P:S>Pr

Strona 40

Programming124NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionSET HTTPS PORTSets the I

Strona 41

Programming125 NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionSET LOG COUNTSets the n

Strona 42

Programming126NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionSET THRESHOLDSets the Ma

Strona 43

Programming127 NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionSHOW BUFFERSDisplays a

Strona 44 - NetLinx Security Terms

Programming128NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionSHOW LOGDisplays the log

Strona 45 - Browser Application Frames

Programming129 NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionSHOW MAX BUFFERSDisplay

Strona 46 - Log In/Log Out fields

Introduction4NI-3101-SIG Signature Series NetLinx Integrated ControllerNI-3101-SIG Specifications (Cont.)IR/Serial (Ports 9 - 16) Eight IR/Serial cont

Strona 47 - Web Control

Programming130NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration Port Commands (Cont.)Command DescriptionSHOW SYSTEMProvides a li

Strona 48 - Security Features

Programming131 NI-3101-SIG Signature Series NetLinx Integrated ControllerESC Pass CodesThere are 'escape' codes in the pass mode. These code

Strona 49

Programming132NI-3101-SIG Signature Series NetLinx Integrated ControllerLED Disable/Enable Send_CommandsThe following commands enable or disable the L

Strona 50 - System Level Security Page

Programming133 NI-3101-SIG Signature Series NetLinx Integrated ControllerRS-232/422/485 Send_Commands (Cont.)Command DescriptionCHARDSet the delay tim

Strona 51

Programming134NI-3101-SIG Signature Series NetLinx Integrated ControllerRS-232/422/485 Send_Commands (Cont.)Command DescriptionRXOFFDisable the transm

Strona 52 - Port Communication Settings

Programming135 NI-3101-SIG Signature Series NetLinx Integrated ControllerRS-232/422/485 Send_String Escape Sequences This device also has some special

Strona 53 - ICSP Authentication

Programming136NI-3101-SIG Signature Series NetLinx Integrated ControllerIR / Serial Ports Channels IR/Serial Send_CommandsThe following IR and IR/Seri

Strona 54 - Manage Group Page

Programming137 NI-3101-SIG Signature Series NetLinx Integrated ControllerIR/Serial Send_Commands (Cont.)Command DescriptionCHSend IR pulses for the se

Strona 55

Programming138NI-3101-SIG Signature Series NetLinx Integrated ControllerIR/Serial Send_Commands (Cont.)Command DescriptionGET BAUDGet the IR port’s cu

Strona 56

Programming139 NI-3101-SIG Signature Series NetLinx Integrated ControllerIR/Serial Send_Commands (Cont.)Command DescriptionPONTurn On a device connect

Strona 57

Installation and Upgrading5NI-3101-SIG Signature Series NetLinx Integrated ControllerInstallation and UpgradingDevice:Port:System (D:P:S)A device is a

Strona 58

Programming140NI-3101-SIG Signature Series NetLinx Integrated ControllerIR/Serial Send_Commands (Cont.)Command DescriptionSET IO LINKLink an IR or Ser

Strona 59

Programming141 NI-3101-SIG Signature Series NetLinx Integrated ControllerIR/Serial Send_Commands (Cont.)Command DescriptionXCHMChanges the IR output p

Strona 60

Programming142NI-3101-SIG Signature Series NetLinx Integrated ControllerInput/Output Send_CommandsThe following Send_Commands program the I/O ports on

Strona 61 - System Settings

Troubleshooting143NI-3101-SIG Signature Series NetLinx Integrated ControllerTroubleshootingThis section describes the solutions to possible hardware/f

Strona 62 - Manage System Page Components

Troubleshooting144NI-3101-SIG Signature Series NetLinx Integrated Controller Troubleshooting Information (Cont.)Symptom SolutionI can’t connect to my

Strona 63

Troubleshooting145NI-3101-SIG Signature Series NetLinx Integrated Controller

Strona 64 - Modify System/Date dialog

9/11 ©2011 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without not

Strona 65 - Change System Number dialog

Installation and Upgrading6NI-3101-SIG Signature Series NetLinx Integrated Controller3. Thread the cables through the opening in the equipment rack. A

Strona 66 - Control/Emulate dialog

Connections and Wiring7NI-3101-SIG Signature Series NetLinx Integrated ControllerConnections and WiringSetting the Configuration DIP Switch for the Co

Strona 67

Connections and Wiring8NI-3101-SIG Signature Series NetLinx Integrated ControllerModes and Front Panel LED Blink PatternsThe following table lists the

Strona 68

Connections and Wiring9NI-3101-SIG Signature Series NetLinx Integrated ControllerThe AXlink port can be used to supply power to downstream AXlink-comp

Strona 69

AMX Limited Warranty and DisclaimerThis Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Part

Strona 70

Connections and Wiring10NI-3101-SIG Signature Series NetLinx Integrated ControllerUsing the 4-pin mini-Phoenix connector for data and powerConnect the

Strona 71 - Manage System - Server

Connections and Wiring11NI-3101-SIG Signature Series NetLinx Integrated ControllerDB9 Device Port: Connections and WiringFIG. 7 shows the connector pi

Strona 72

Connections and Wiring12NI-3101-SIG Signature Series NetLinx Integrated ControllerInput/Output (I/O) Port: Connections and WiringThe I/O port responds

Strona 73

Connections and Wiring13NI-3101-SIG Signature Series NetLinx Integrated ControllerThe IR/Serial connector wiring specifications are listed in the foll

Strona 74

Connections and Wiring14NI-3101-SIG Signature Series NetLinx Integrated ControllerLAN LEDs LAN ports used by the Integrated ControllersReplacing t

Strona 75 - Server Certificate Entries

Connections and Wiring15NI-3101-SIG Signature Series NetLinx Integrated Controller3. Remove the rear panel from the device, and then disconnect the NX

Strona 76

Connections and Wiring16NI-3101-SIG Signature Series NetLinx Integrated Controller

Strona 77

Configuration and Firmware Update17NI-3101-SIG Signature Series NetLinx Integrated ControllerConfiguration and Firmware UpdateOverviewThis section ref

Strona 78

Configuration and Firmware Update18NI-3101-SIG Signature Series NetLinx Integrated Controller7. Set the COM port parameters for the selected COM port

Strona 79 - Export SSL Certificate dialog

Configuration and Firmware Update19NI-3101-SIG Signature Series NetLinx Integrated Controller 2. Select the Change System selection box from the Syst

Strona 80 - Import SSL Certificate dialog

AMX Software License and Warranty Agreement• LICENSE GRANT. AMX grants to Licensee the non-exclusive right to use the AMX Software in the manner descr

Strona 81 - Network Settings dialog

Configuration and Firmware Update20NI-3101-SIG Signature Series NetLinx Integrated ControllerUsing Multiple NetLinx MastersWhen using more than one Ma

Strona 82 - URL List dialog

Configuration and Firmware Update21NI-3101-SIG Signature Series NetLinx Integrated ControllerRecommended NetLinx Device Numbers Using the ID Button to

Strona 83 - Device Number dialog

Configuration and Firmware Update22NI-3101-SIG Signature Series NetLinx Integrated Controller5. Press the NI Controller’s ID button to assign the new

Strona 84 - Log dialog

Configuration and Firmware Update23NI-3101-SIG Signature Series NetLinx Integrated Controller3. Click Done to close the Device Addressing dialog.4. Cl

Strona 85

Configuration and Firmware Update24NI-3101-SIG Signature Series NetLinx Integrated Controller4. Note the obtained IP Address (greyed-out and read-only

Strona 86 - 2. Click the Remove button

Configuration and Firmware Update25NI-3101-SIG Signature Series NetLinx Integrated Controller2. Verify that both the System number corresponds to the

Strona 87

Configuration and Firmware Update26NI-3101-SIG Signature Series NetLinx Integrated ControllerCommunicating with the NI Device via an IPWhether the on-

Strona 88

Configuration and Firmware Update27NI-3101-SIG Signature Series NetLinx Integrated Controller7. Click the New button to open the New TCP/IP Setting di

Strona 89

Configuration and Firmware Update28NI-3101-SIG Signature Series NetLinx Integrated Controller13. Click OK to save the newly entered information and re

Strona 90 - Discovery Pages

Configuration and Firmware Update29NI-3101-SIG Signature Series NetLinx Integrated ControllerUpgrading the On-board Master Firmware via an IPThe on-bo

Strona 92

Configuration and Firmware Update30NI-3101-SIG Signature Series NetLinx Integrated Controllervalue listed within the active System folder in the OnLin

Strona 93

Configuration and Firmware Update31NI-3101-SIG Signature Series NetLinx Integrated Controller17. Right-click the System number and select Refresh Syst

Strona 94

Configuration and Firmware Update32NI-3101-SIG Signature Series NetLinx Integrated Controller8. Select the Integrated Controller’s (_X00) from the Fil

Strona 95

NetLinx Security within the Web Server33NI-3101-SIG Signature Series NetLinx Integrated ControllerNetLinx Security within the Web ServerNetLinx Master

Strona 96 - Manage Device Bindings page

NetLinx Security within the Web Server34NI-3101-SIG Signature Series NetLinx Integrated ControllerNetLinx Security TermsThe following table lists some

Strona 97

NetLinx Security within the Web Server35NI-3101-SIG Signature Series NetLinx Integrated ControllerBrowser Application FramesA web page (FIG. 32) can b

Strona 98 - View Discovered Devices page

NetLinx Security within the Web Server36NI-3101-SIG Signature Series NetLinx Integrated ControllerThere is no limit to the number of concurrent logins

Strona 99 - Add New Device page

NetLinx Security within the Web Server37NI-3101-SIG Signature Series NetLinx Integrated ControllerMaster Firmware Security Access ParametersMaster S

Strona 100

NetLinx Security within the Web Server38NI-3101-SIG Signature Series NetLinx Integrated ControllerClicking on a G4 WebControl link opens a separate br

Strona 101

NetLinx Security within the Web Server39NI-3101-SIG Signature Series NetLinx Integrated ControllerThe following table lists the NetLinx System Securit

Strona 102 - 1. Launch a web browser

Table of ContentsiNI-3101-SIG Signature Series NetLinx Integrated ControllerTable of ContentsIntroduction ...

Strona 103

NetLinx Security within the Web Server40NI-3101-SIG Signature Series NetLinx Integrated ControllerFIG. 36 System Level Security - Enable/Disable Syst

Strona 104 - Certificate Import Wizard

NetLinx Security within the Web Server41NI-3101-SIG Signature Series NetLinx Integrated ControllerThe following graphic illustrates the Ports which

Strona 105

NetLinx Security within the Web Server42NI-3101-SIG Signature Series NetLinx Integrated ControllerSetting the system security options for a NetLinx Ma

Strona 106 - Connection Details dialog

NetLinx Security within the Web Server43NI-3101-SIG Signature Series NetLinx Integrated Controllerparameters. If the Configuration option is enabled a

Strona 107

NetLinx Security within the Web Server44NI-3101-SIG Signature Series NetLinx Integrated ControllerSecurity - Group Level Security pageTo access this p

Strona 108

NetLinx Security within the Web Server45NI-3101-SIG Signature Series NetLinx Integrated ControllerConfigure Group Properties PageFeature DescriptionCo

Strona 109 - NetLinx Security Features

NetLinx Security within the Web Server46NI-3101-SIG Signature Series NetLinx Integrated ControllerAdding a new Group1.Click the Group Level link (from

Strona 110

NetLinx Security within the Web Server47NI-3101-SIG Signature Series NetLinx Integrated Controllergive them a new group or assign them (none) as a gro

Strona 111

NetLinx Security within the Web Server48NI-3101-SIG Signature Series NetLinx Integrated Controller Configure User Properties PageFeature Descript

Strona 112

NetLinx Security within the Web Server49NI-3101-SIG Signature Series NetLinx Integrated ControllerAdding a new UserThe information entered within this

Strona 113

iiNI-3101-SIG Signature Series NetLinx Integrated ControllerTable of ContentsResetting the Factory Default System and Device Values...

Strona 114 - Access Rights Menu

NetLinx Security within the Web Server50NI-3101-SIG Signature Series NetLinx Integrated Controller8. Click the Update button to save the changes to th

Strona 115

NetLinx Security within the Web Server51NI-3101-SIG Signature Series NetLinx Integrated Controller3. Click the Delete button to remove the selected us

Strona 116

NetLinx Security within the Web Server52NI-3101-SIG Signature Series NetLinx Integrated Controller Manage System Page ComponentsFeature Descript

Strona 117

NetLinx Security within the Web Server53NI-3101-SIG Signature Series NetLinx Integrated ControllerManage System Page Components (Cont.)Feature Descrip

Strona 118

NetLinx Security within the Web Server54NI-3101-SIG Signature Series NetLinx Integrated ControllerManage System - System Menu ButtonsThese buttons app

Strona 119 - Main Security Menu

NetLinx Security within the Web Server55NI-3101-SIG Signature Series NetLinx Integrated Controller4. Enter a new numeric value into the New System Num

Strona 120

NetLinx Security within the Web Server56NI-3101-SIG Signature Series NetLinx Integrated Controller5. Select either the Control or Emulate option. T

Strona 121 - Help menu

NetLinx Security within the Web Server57NI-3101-SIG Signature Series NetLinx Integrated Controller 11. Within the Command and String fields, you can

Strona 122 - Help Menu Options (Cont.)

NetLinx Security within the Web Server58NI-3101-SIG Signature Series NetLinx Integrated ControllerSetting up and removing a Diagnostic Filter1.Setup a

Strona 123 - Logging Into a Session

NetLinx Security within the Web Server59NI-3101-SIG Signature Series NetLinx Integrated ControllerPress the down arrow (adjacent to the Preset drop-

Strona 124 - Setup Security

Table of ContentsiiiNI-3101-SIG Signature Series NetLinx Integrated ControllerSSL Server Certificate Creation Procedures...

Strona 125 - Programming

NetLinx Security within the Web Server60NI-3101-SIG Signature Series NetLinx Integrated Controller5. Remove a diagnostic filter by clicking the Modify

Strona 126 - Master Send_Commands (Cont.)

NetLinx Security within the Web Server61NI-3101-SIG Signature Series NetLinx Integrated ControllerSetting the Master’s Port ConfigurationsManage Syste

Strona 127 - Using the ID Button

NetLinx Security within the Web Server62NI-3101-SIG Signature Series NetLinx Integrated ControllerModifying the Server Port Settings1.From within the

Strona 128 - Configuration Port Commands

NetLinx Security within the Web Server63NI-3101-SIG Signature Series NetLinx Integrated Controller4. Once an authorized user has modified any of the s

Strona 129

NetLinx Security within the Web Server64NI-3101-SIG Signature Series NetLinx Integrated ControllerOnline Tree refreshes with the current system inform

Strona 130

NetLinx Security within the Web Server65NI-3101-SIG Signature Series NetLinx Integrated ControllerServer Certificate EntriesFeature DescriptionServer

Strona 131

NetLinx Security within the Web Server66NI-3101-SIG Signature Series NetLinx Integrated ControllerServer - Display SSL Server Certificate Information1

Strona 132

NetLinx Security within the Web Server67NI-3101-SIG Signature Series NetLinx Integrated ControllerServer - Regenerating an SSL Server Certificate Requ

Strona 133 - SET DNS [0:1:0]

NetLinx Security within the Web Server68NI-3101-SIG Signature Series NetLinx Integrated Controller10. Choose Create Request from the drop-down list.11

Strona 134 - SET IP [0:1:0]

NetLinx Security within the Web Server69NI-3101-SIG Signature Series NetLinx Integrated Controller3. Place your cursor within the certificate text fie

Strona 135

ivNI-3101-SIG Signature Series NetLinx Integrated ControllerTable of ContentsInitial Setup via a Terminal Connection...

Strona 136

NetLinx Security within the Web Server70NI-3101-SIG Signature Series NetLinx Integrated Controller2. Navigate to the Server Certificate page by clicki

Strona 137

NetLinx Security within the Web Server71NI-3101-SIG Signature Series NetLinx Integrated ControllerManage System - Device Menu ButtonsThe Device Menu b

Strona 138

NetLinx Security within the Web Server72NI-3101-SIG Signature Series NetLinx Integrated Controller8. Return to the System menu by clicking on the purp

Strona 139

NetLinx Security within the Web Server73NI-3101-SIG Signature Series NetLinx Integrated Controller10. Confirm that the newly added URLs appear within

Strona 140

NetLinx Security within the Web Server74NI-3101-SIG Signature Series NetLinx Integrated ControllerDevice Menu - Controlling or Emulating a deviceRefer

Strona 141 - ESC Pass Codes

NetLinx Security within the Web Server75NI-3101-SIG Signature Series NetLinx Integrated ControllerAdding a new license1.Click on the System Settings &

Strona 142 - RS-232/422/485 Send_Commands

NetLinx Security within the Web Server76NI-3101-SIG Signature Series NetLinx Integrated ControllerRemoving a license1.Click on the System Settings >

Strona 143

NetLinx Security within the Web Server77NI-3101-SIG Signature Series NetLinx Integrated Controller A large number of NDP-capable devices on the LAN

Strona 144

NetLinx Security within the Web Server78NI-3101-SIG Signature Series NetLinx Integrated ControllerManage NetLinx Devices - Displaying NDP-capable devi

Strona 145

NetLinx Security within the Web Server79NI-3101-SIG Signature Series NetLinx Integrated ControllerManage NetLinx Devices - Obtaining NetLinx Device in

Strona 146 - IR/Serial Send_Commands

Table of ContentsvNI-3101-SIG Signature Series NetLinx Integrated ControllerWindowsTM client programs...

Strona 147

NetLinx Security within the Web Server80NI-3101-SIG Signature Series NetLinx Integrated ControllerSystem Settings - Manage Other Devices - Dynamic Dev

Strona 148

NetLinx Security within the Web Server81NI-3101-SIG Signature Series NetLinx Integrated ControllerManage Other Devices Page (Cont.)Feature Description

Strona 149

NetLinx Security within the Web Server82NI-3101-SIG Signature Series NetLinx Integrated ControllerManage Other Devices Page (Cont.)Feature Description

Strona 150

NetLinx Security within the Web Server83NI-3101-SIG Signature Series NetLinx Integrated ControllerWhat is Dynamic Device Discovery?The Dynamic Device

Strona 151

NetLinx Security within the Web Server84NI-3101-SIG Signature Series NetLinx Integrated ControllerWhat is the difference between Program and Run-time

Strona 152 - Input/Output Send_Commands

NetLinx Security within the Web Server85NI-3101-SIG Signature Series NetLinx Integrated ControllerManage Other Devices - Manage Device BindingsTo acce

Strona 153 - Troubleshooting

NetLinx Security within the Web Server86NI-3101-SIG Signature Series NetLinx Integrated ControllerThis code would have given the Master a previous “he

Strona 154

NetLinx Security within the Web Server87NI-3101-SIG Signature Series NetLinx Integrated ControllerWhat are Application Devices and their association s

Strona 155

NetLinx Security within the Web Server88NI-3101-SIG Signature Series NetLinx Integrated Controllervirtual device). If the Cancel button is selected, t

Strona 156

NetLinx Security within the Web Server89NI-3101-SIG Signature Series NetLinx Integrated ControllerMousing-over a listed module entry presents a popup

Komentarze do niniejszej Instrukcji

Brak uwag