Terminal (Telnet) Commands
54
ICSLan Device Control Boxes
In this case, do not enter anything for the username when prompted. Simply press <Enter>, which
will then present the password prompt. Here, the defined password must be entered, in order to
successfully open the Telnet session.
Additional Notes
Both the Telnet username and password are case-sensitive.
Three consecutive, unsuccessful attempts to log in to Telnet will cause the Telnet window to close.
Re-launching Telnet will again present the login prompt, with a fresh "batch" of login attempts.
If Telnet login fails because of an incorrect username, you will receive the "Invalid Password"
message (as opposed to an "Invalid Username" message).
Setting a Telnet Username and Password
To set a Telnet username and password:
1. Establish a terminal connection via Telnet.
2. Type Set Telnet Username, and press <Enter>.
a. The program will prompt you to enter a new Telnet user name.
b. Enter a username and press <Enter>.
c. The program will indicate that the username is being stored.
3. Type Set Telnet Password, and press <Enter>.
a. The program will prompt you to enter a password.
b. Enter a password and press <Enter>.
c. The program will prompt you to re-enter the Telnet password.
d. Re-enter the password and press <Enter>.
e. The program will indicate that the password is being stored.
Telnet Commands
The commands listed in the following table can be sent directly to the EXB Module via a Telnet terminal
session.
In your terminal program, type “Help” or a question mark (“?”) and <Enter> to access the Help Menu, and
display the Program port commands described below:
Press <Enter> twice when asked to enter the password to clear both the telnet
username and password.
Terminal Commands
Command Description
? or Help Display this list of commands.
DEVICE STATUS Display device status of a specified device, port, system (<D:P:S>).
Note: Devices other than the EXB-xxx module itself will be ignored.
Example:
>device status 10102:1:1
Device Status
-------------
Device 10102 AMX LLC,EXB-IRS4,v0.0.25.0 contains 5 Ports.
Port 1 - Channels:255 Levels:8
MaxStringLen=64 Types=8 bit MaxCommandLen=64 Types=8 bit
The following input channels are on:None
The following output channels are on:None
Level 1=0 Supported data types=UByte,UInt
Level 2=0 Supported data types=UByte,UInt
Level 3=0 Supported data types=UByte,UInt
Level 4=0 Supported data types=UByte,UInt
Level 5=0 Supported data types=UByte,UInt
Level 6=0 Supported data types=UByte,UInt
Level 7=0 Supported data types=UByte,UInt
Level 8=0 Supported data types=UByte,UInt
>
Komentarze do niniejszej Instrukcji