Synchronous Motors Ver. 0002 SM - 5
Mo, Io: Stall torque, with Io current permitted without time limit
Mp, Imax: Peak torque and maximum current
Very important: Imax must never be exceeded, because it would demagnetize the rotor.
nN: Rated (nominal) turning speed.
Pow: Rated Power = Mo •
n
N
/ 9550
KT: Torque constant. Torque generated depending on the supplied current.
tac: Acceleration time of the motor from 0 rpm up to its rated speed at its maximum torque.
L, R: Winding inductance and resistance between phases.
J: Rotor inertia.
P: Weight.
mm
Kg·m
2
Nm
°C
Kw
÷
25.4
÷
0.113
x
1.8
inch
lb·in·sec
2
lb·in
°F
HP
÷
0.113
÷
0.746
+
32
Metric Imperial
Conversion table
to
NON-VENTILATED
Power conn
MOTORS
FXM73.12A.xx.xx0
FXM73.20A.xx.xx0
FXM73.30A.xx.xx0
FXM73.40A.xx.xx0
FXM74.12A.xx.xx0
FXM74.20A.xx.xx0
FXM74.30A.xx.xx0
FXM74.40A.xx.xx0
FXM75.12A.xx.xx0
FXM75.20A.xx.xx0
FXM75.30A.xx.xx0
FXM75.40A.xx.xx0 *
FXM76.12A.xx.xx0
FXM76.20A.xx.xx0
FXM76.30A.xx.xx0
FXM76.40A.xx.xx0 *
FXM77.12A.xx.xx0
FXM77.20A.xx.xx0
FXM77.30A.xx.xx0 *
FXM77.40A.xx.xx0 *
FXM78.12A.xx.xx0
FXM78.20A.xx.xx0
FXM78.30A.xx.xx0 *
FXM78.40A.xx.xx0 *
(*)
Stall Torque
Peak
Torque
Rated
Speed
Stall Current
Peak
Current
Power
Torque
Constant
Acceleration
Time
Inductance
inter-phases
Resistance
inter-phases
Inertia
Weight
Peak Torque (Nm) for 0.5 seconds.
Mo Mp
n
N
Io Imax Pow KT tac L R J P 1.08 1.15 1.25
1.35 2.50 2.75 3.100 3,150
-Nm- -Nm- -rpm- -A- -A- -kW- Nm/A -ms- -mHr- Ohms Kg.cm2 -Kg- -Nm- -Nm- -Nm- -Nm- -Nm- -Nm- -Nm- -Nm-
19,5 97,5 1200 4,7 23,5 2,5 4,1 11,9 58,0 4,8 92,0 29,0 62,2
97,5
19,5 97,5 2000 7,8 39,0 4,1 2,5 19,8 22,0 1,8 92,0 29,0 62,5 87,5
97,5
19,5 97,5 3000 11,3 56,5 6,1 1,7 29,6 10,0 0,8 92,0 29,0 43,1 60,4 86,3
97,5
19,5 97,5 4000 15,4 77,0 8,2 1,3 39,5 6,0 0,5 92,0 29,0 44,3 63,3 95,0
97,5
26,0 130,0 1200 6,2 31,0 3,3 4,2 11,6 44,0 3,1 120,0 31,6 62,9 104,8
130,0
26,0 130,0 2000 10,4 52,0 5,4 2,5 19,3 16,0 1,2 120,0 31,6 62,5 87,5 125,0
130,0
26,0 130,0 3000 15,4 77,0 8,2 1,7 29,0 8,0 0,6 120,0 31,6 59,1 84,4 126,6
130,0
26,0 130,0 4000 20,6 103,0 10,9 1,3 38,6 4,0 0,3 120,0 31,6 63,1 94,7 126,2
130,0
32,0 160,0 1200 7,7 38,5 4,0 4,2 12,6 34,0 2,2 160,0 36,0 103,9 145,5
160,0
32,0 160,0 2000 12,9 64,5 6,7 2,5 20,9 13,0 0,8 160,0 36,0 86,8 124,0
160,0
32,0 160,0 3000 19,3 96,5 10,1 1,7 31,4 6,0 0,4 160,0 36,0 82,9 124,4
160,0
32,0 160,0 4000 25,3 126,5 13,4 1,3 41,9 3,0 0,2 160,0 36,0 94,9 126,5
160,0
39,0 195,0 1200 9,3 46,5 4,9 4,2 12,2 29,0 1,8 189,0 40,0 104,8 146,8
195,0
39,0 195,0 2000 15,4 77,0 8,2 2,5 20,3 12,0 0,7 189,0 40,0 88,6 126,6 189,9
195,0
39,0 195,0 3000 22,6 113,0 12,3 1,7 30,4 5,0 0,3 189,0 40,0 86,3 129,4 172,6
195,0
39,0 195,0 4000 31,0 155,0 16,3 1,3 40,6 3,0 0,2 189,0 40,0 94,4 125,8 188,7
45,0 225,0 1200 10,9 54,5 5,7 4,1 13,0 25,0 1,5 232,0 43,0 103,2 144,5 206,4
225,0
45,0 225,0 2000 17,3 86,5 9,4 2,6 21,6 10,0 0,6 232,0 43,0 91,0 130,1 195,1
225,0
45,0 225,0 3000 26,5 132,5 14,1 1,7 32,4 4,0 0,3 232,0 43,0 127,4 169,8
225,0
45,0 225,0 4000 35,7 178,5 18,8 1,3 43,2 3,0 0,1 232,0 43,0 94,5 126,1 189,1
52,0 260,0 1200 12,5 62,5 6,5 4,2 13,0 23,0 1,3 270,0 47,0 104,0 145,6 208,0
260,0
52,0 260,0 2000 20,6 103,0 10,9 2,5 21,7 8,0 0,4 270,0 47,0 126,2 189,3 252,4
260,0
52,0 260,0 3000 31,0 155,0 16,3 1,7 32,6 4,0 0,2 270,0 47,0 125,8 167,7 251,6
52,0 260,0 4000 41,2 206,0 21,8 1,3 43,5 2,0 0,1 270,0 47,0 126,2 189,3
Motors with a power "base" which need to be connected via MC 46 type socket. All the others with MC 23.
In bold, the combinations where the drive automatically limits its peak current to avoid damaging the motor.
Komentarze do niniejszej Instrukcji