18
timeout values are 10 seconds for a CC16 and 30 seconds for a CC64. The backlight time for a CC64
can still be adjusted on the hardware by pressing banks 1+4 simultaneously but any changes made here
will be overwritten when a file is uploaded.
9. ESP IP Address Changes - Changing the ESP’s IP address no longer requires a hardware power-
cycle. After changing the IP address the user is presented with the option of rebooting the ESP, following
the reboot the new IP address is active.
10. Improved CC-4/Potentiometer GPI Mapping – The operation of the CC-4 user interface has been
improved to make better use of the low volume regions of the control. Previously the 8-12 o’clock region
produced a minimal increase in volume. The CC-4 can also attain a minimum volume of –inf dB versus -
59.5db and can break out of a mute state at minimum volume.
11. Meter Blocks Optimized – The signal meter blocks have been optimized and use fewer DSP
resources.
12. DS16 Pendant EQ – EQ curve for pendant mounted DS16s has been added.
Bug fixes
1. An issue with the serial protocol “Get Level” command reporting incorrect data has been resolved.
(#281)
2. Incorrect CC-64 labels when the bank controls were assigned with level- or mute-only have been
resolved. (#270)
3. Help File now opens correctly when using Windows Vista (#306)
4. The ‘Network Setup’ and ‘Update Firmware’ utilities now operate correctly when using Windows Vista
(#248)
5. Issues with ControlSpace Designer minimizing have been fixed (#307)
6. An issue whereby uploading a file could cause the system to hang when using Windows Vista has
been resolved (#302)
7. An issue with CC-64 controlling selectors across multiple ESPs has been resolved (#286)
8. An issue with CC-64 not correctly changing group levels that were set to –inf at power-up has been
resolved (#278)
9. Incorrect reporting of surround card status via the serial port has been resolved (#190)
10. The CC-64 lock property now functions properly in multi-ESP designs (#238)
11. An issue whereby gain levels set to –inf would be saved as -8dB has been resolved (#291)
12. The sequence in which the Room Combining Mixer properties were recalled by a parameter set
caused the ‘Local Select’ value to be overwritten. This has now been corrected (#315)
13. An issue with the serial Group Mute (SN/GN) command not operating correctly across multiple ESP-
88s has been resolved
v2.050 (November, 2008)
New Features